Pentair IC20 User Manual Page 27

  • Download
  • Add to my manuals
  • Print
  • Page
    / 48
  • Table of contents
  • TROUBLESHOOTING
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 26
19
IntelliChlor Electronic Chlorine Generator Installation and Users Guide
General Recommendations
After new pool construction has been completed, before installing the IntelliChlor
Electronic Chlorine
Generator, install the IntelliChlor “dummy cell” (P/N 520588) to remove debris from the pipes for
thirty (30) days and to allow sufficient time for the pool plaster (or other similar material) to properly
cure and seal.
Read and keep this Installation and Users Guide in a safe place.
Increase Sanitizer Output level as necessary after heavy rain (outdoor pools) and return to normal
afterwards.
Increase Sanitizer Output level when air and water temperature rise.
Increase Sanitizer Output level when number of pool users increase.
Use Cyanuric Acid ONLY as necessary to stabilize chlorine in the pool water in outdoor pools.
NOTE: DO NOT USE CYANURIC ACID IN INDOOR POOLS.
Once a month take a pool water sample to a pool professional for a complete analysis.
General Cautions
Do not get fertilizer in your pool. Fertilizers contain nitrates, which cause a high chlorine demand.
Never use dry acid to adjust pH in arid geographic areas with excessive evaporation and minimal
dilution of pool water with fresh water. A buildup of byproducts can damage the IECG.
Do not add any pool water balancing chemicals (including salt) unless the IECG is switched off.
Do not let the Cyanuric Acid level drop below 50 ppm in outdoor pools. NOTE: DO NOT USE
CYANURIC ACID IN INDOOR POOLS.