Summary of Contents

Page 1 - ThermalFlo

IMPORTANT SAFETY INSTRUCTIONSREAD AND FOLLOW ALL INSTRUCTIONSSAVE THESE INSTRUCTIONSInstallationandUser's GuideThermalFlo™Heat Pump

Page 2 - Customer Service

2ThermalFlo Installation and User’s GuideGeneral Features• Dual digital thermostats offer precise temperature control to maintain the desired separate

Page 3 - Contents

3ThermalFlo Installation and User’s GuideSection 2InstallationThe following general information describes how to install the ThermalFlo heat pump.Note

Page 4 - Contents, continued

4ThermalFlo Installation and User’s GuideThermalFlo Heat Pump Dimensions38.7"A4.5"9.25"11.25"32.0"30.7"18.0"6.5&quo

Page 5 - IMPORTANT SAFETY PRECAUTIONS

5ThermalFlo Installation and User’s GuideClearancesAll criteria given in the following sections reflect minimum clearances. However, each installation

Page 6 - (continued)

6ThermalFlo Installation and User’s GuideHEAT PUMPCLAMPSHEAT PUMPCLAMPSFigure 4.Drainage and CondensationCondensation will occur from the evaporator c

Page 7

7ThermalFlo Installation and User’s GuideHEAT PUMPANCHOR CLAMPAIR COIL GUARDAIRCOILBOLT ANCHOR(installer provided)HEAT PUMPBASE1-3/8" HEX BOLT(in

Page 8 - Warranty Information

8ThermalFlo Installation and User’s GuideWater Connections at the Heat PumpTwo inch Quick Connect fittings have been installed on the water inletand o

Page 9 - Introduction

9ThermalFlo Installation and User’s GuideMultiple Unit InstallationHeat Pump, Heater and/or Solar CombinationIn certain regions of the country it may

Page 10 - General Features

10ThermalFlo Installation and User’s GuideMultiple Heat Pump ConnectionsAll plumbing on multiple heat pump installations must be done in parallel see

Page 11 - Installation

11ThermalFlo Installation and User’s GuideElectrical Connections WARNING —Risk of electrical shock or electrocution.This heat pump contains wiring tha

Page 12 - Location

© 2006 Pentair Water Pool and Spa, Inc. All rights reserved.This document is subject to change without notice.1620 Hawkins Ave., Sanford, NC 27330 •

Page 13 - Equipment Pad

12ThermalFlo Installation and User’s GuideWiring Diagram473073ContactorCompressorIncoming 220 VACPower ConnectionRCSREMOTE10KThermistor123456Capacitor

Page 14 - Figure 4

13ThermalFlo Installation and User’s GuideRelay Remote ControlsElectrical wiring must be in accordance with the latest edition of the NEC (NFPA 70) in

Page 15 - Figure 5

14ThermalFlo Installation and User’s GuideConnecting the ThermalFlo to the IntelliTouch® or EasyTouch® Load CenterTo connect the ThermalFlo cable to t

Page 16 - Outlet Union

15ThermalFlo Installation and User’s GuideSection 3Operating ThermalFloThis section describes how to operate the ThermalFlo heat pump.Initial Start-up

Page 17 - Figure 8

16ThermalFlo Installation and User’s GuideOperating the ControllerAn advanced microprocessor based controller that provides a sophisticated yet simple

Page 18 - 24"

17ThermalFlo Installation and User’s GuideIndicator Lights / LEDsNine lights can be seen from the front of the control panel. Five are system indicato

Page 19 - Electrical Connections

18ThermalFlo Installation and User’s GuideOperationTemperature SettingThe heat pump comes factory set at 78º F. for POOL mode and 100º F. for SPA mode

Page 20 - Figure 11

19ThermalFlo Installation and User’s GuideTroubleshootingThe control panel contains a three digit LED display. These LEDs display temperatures, lock

Page 21 - Figure 12

20ThermalFlo Installation and User’s GuideWater Pressure Switch Adjustment CAUTION — The water pressure switch should be adjusted to turn the heater o

Page 22 - Figure 13

21ThermalFlo Installation and User’s GuideSection 4General MaintenanceWater ChemistryProper chemical balances are necessary for sanitary bathing condi

Page 23 - Figure 14

iThermalFlo Installation and User’s GuideContentsImportant Safety Precautions ...

Page 24 - Figure 15. Main Control Panel

22ThermalFlo Installation and User’s GuideSpring Start-UpIf your heat pump has been winterized, perform the following steps when starting the system i

Page 25 - Indicator Lights / LEDs

23ThermalFlo Installation and User’s GuideProfessional Maintenance and ServiceThe Pentair ThermalFlo Heat Pump is one of the most efficient ways to he

Page 26 - Operation

24ThermalFlo Installation and User’s Guide

Page 27 - Troubleshooting

25ThermalFlo Installation and User’s GuideSection 5TroubleshootingUse the following troubleshooting information to resolve possible problems with your

Page 28

26ThermalFlo Installation and User’s GuideRemote, Pool or Spa light ON.Water Pressure light ON.Thermostat light OFF.EO1 ErrorUnit will not run.Remote,

Page 29 - Figure 16

27ThermalFlo Installation and User’s GuideCompressor will not start. Fan comeson, compressor attempts to start butunit shuts all the way off (and or c

Page 30

28ThermalFlo Installation and User’s GuideSection 6Replacement PartsIllustrated PartsDETAIL ASEE DETAIL A

Page 31 - EVAPORATOR

29ThermalFlo Installation and User’s GuideReplacement Parts ListItem No. Part No. Part Description1 470439 NUT, 10-32 SS ACORN2 473368 GUARD, FAN3 470

Page 32

30ThermalFlo Installation and User’s GuideNotes

Page 34

iiThermalFlo Installation and User’s GuideContents, continuedSection 3: Operating the ThermalFlo ...

Page 35

P/N 473426 Rev. C 10/19/06

Page 36 - Replacement Parts

iiiThermalFlo Installation and User’s GuideIMPORTANT SAFETY PRECAUTIONSCodes and StandardsThe ThermalFlo HP heat pump is listed by ETL as complying wi

Page 37 - Replacement Parts List

ivThermalFlo Installation and User’s GuideIMPORTANT SAFETY PRECAUTIONS (continued)Consumer Information and SafetyThe ThermalFlo series of heat pumps a

Page 38

vThermalFlo Installation and User’s GuideIMPORTANT SAFETY PRECAUTIONS (continued)Swimming Pool Energy Saving TipsIt is important to note that a heat p

Page 39

viThermalFlo Installation and User’s GuideIMPORTANT SAFETY PRECAUTIONS (continued)General Installation Information1. Installation and service must be

Page 40

1ThermalFlo Installation and User’s GuideSection 1IntroductionThermalFlo OverviewThe ThermalFlo heat pump gets electrical power from an external sourc