6. Assemble the strainer pot assembly, if
included, to the pump. Be sure to install the
O-Ring (included with the strainer pot
assembly) over the protruding plastic ring
on the front of the pump housing before
mounting the strainer pot. Properly position
the strainer pot to the housing and secure in
place using the 8 large flange bolts and
washers included with the strainer pot
assembly. These bolts should not be over
tightened as this could damage the pump.
Proper technique is to lightly snug each bolt
with a wrench. A squealing sound during
tightening of the bolts indicates that the bolts
are being excessively tightened.
7. Place the pump in its final location and ensure
that the mating flanges of the suction and
discharge piping are in line and parallel to the
flanges on the pump. Resolve any problems
with misalignment before bolting the flanges
to the pump.
8. The pump may be secured to bolts buried in
the concrete by using the holes on the
outside of the motor supports.
9. Ensure that the flange gasket is properly positioned between the suction flange of the pump and the flange of
the suction piping. Use only high quality rubber, full diameter flange gaskets with holes for the bolts to pass
through. It may be necessary to hold the gasket in place with either silicone or two or three drops of a
cyanoacrylate (super glue) material. Do not use any other grease or glue as they may contain chemicals that
could attack the plastic material. Install the flange bolts hand tight on the suction side of the pump.
CAUTION On installations where the pump is installed without a strainer pot, use only 6 in. Schedule 40 PVC
pipe when making the final flange connection. Do NOT use Schedule 80 Pipe, as this can cause
interference with the pump housing.
CAUTION Use large diameter flat washers between the hex nut and the pump flanges to properly distribute the
clamping forces on the flange. Tighten the flanges to 20 ft.-lb. unless otherwise specified by the
flange manufacturer. If it is not possible to use a torque wrench then care should be taken not to over
tighten the flange bolts. Failure to follow the above instructions can result in damaging the pump
flange.
10. Properly insert the flange gasket on the discharge port of the pump. Install the flange bolts hand tight on the
discharge flange connection.
11. Inspect both the suction and flange connection to ensure alignment remains acceptable. Take any corrective
action before tightening the flange bolts to the required torque.
CAUTION Suction and discharge piping must be supported by an appropriate system of supports or hangers.
Inadequately supported pipe can cause excessive loads to be transmitted to the pump resulting in a
structural failure of the pump that could result in flooding and property damage.
* INCLUDED WITH STRAINER POT
HEX NUT 5/8-11
P/N 356788 *
P/N 356789 *
P/N 356766 *
5/8" ID X 1-5/16" MIN OD
FLAT WASHER
6" ANSI CLASS 150 FLANGE
SUCTION CONNECTION WITH
STRAINER POT
70 DURO NITRILE OR EPDM
1/8" THICK GASKET
5/8" ID X 1-5/16" MIN OD
FLAT WASHER
HEX HEAD CAP SCREW
5/8-11 X 3-1/4" LG
70 DURO NITRILE OR EPDM
1/8" THICK GASKET
6" ANSI CLASS 150 FLANGE
SUCTION CONNECTION WITHOUT
STRAINER POT
5/8" ID X 1-5/16" MIN OD
FLAT WASHER
HEX HEAD CAP SCREW
5/8-11 X 2-1/4" LG
Figure 1.
Figure 2.
Page view 9
1 2 ... 5 6 7 8 9 10 11 12 13 14 15 ... 27 28

Comments to this Manuals

No comments