EQ Series Pump Installation and Users Guide
Section 6
Servicing
WARNING Risk of electrical shock or electrocution.
This pool pump must be installed by a licensed or certified electrician or a qualified pool
serviceman in accordance with the National Electrical Code and all applicable local codes and
ordinances. Improper installation will create an electrical hazard which could result in death or
serious injury to pool users, installers, or others due to electrical shock, and may also cause
damage to property.
Always disconnect power to the pool pump at the circuit breaker before servicing the pump.
Ensure that the disconnected circuit is locked out or properly tagged so that it cannot be
switched on while you are working on the pump. Failure to do so could result in death or serious
injury to serviceman, pool users or others due to electric shock.
Read all servicing instructions before working on the pump.
The pump is designed to allow for quick servicing of any moving parts without disturbing the plumbing
connections. The pump can be serviced with the common tools that are in nearly every service persons
toolbox. The following sequential instructions are for a complete disassembly in order to replace a failed motor.
The same instructions may be used to perform a partial disassembly to replace any internal component, but
following all steps will not be required.
CAUTION It is recommended that you replace the motor with the Pentair replacement motor as identified in
Section 8. This motor has been thoroughly tested to ensure that it will function appropriately with the
pump under a wide variety of operating conditions. If you choose to use another replacement motor
it is important that the frame type, the HP, the service factor, the voltage, the phase and the motor
speed match exactly to that listed on the original motor. Slight differences in these parameters can
cause the motor to not fit the pump correctly or cause the motor to fail prematurely.